Make your own free website on Tripod.com
 
 

                                                 MC-610 e7/8 test pattern
                                                ---------------------------

yarn carriers:            FFL:    Base 4,5                        FFR:  Choosing  - 8
-------------

                                           1. colour - 3
Stitch cams:
-------------
F2 - jacquard

F3- chosing

F4- 2/l patent

F5- schema-z

Program knit a square of 8 needles s wide, because the modelling platinum has

8 feet. The location of the trouble determines the malfunctioneng magnet,

belonging to the given numbers platinum foot.

Double stitch - slow function of magnet

Missing stitch - contact trouble

The colour of the square shows the work unit.

In case there is a problem in the paires line, the trouble is when going from

the right to the left, if it is in the unpaired line, the trouble is when

going from the left to the right.

The program tests both the enterior and the posterior needlebed, and after

the patent it begins with the anterior needlebed.
 
 
 

                                             MC-640 e7/8 test pattern
                                            ----------------------------

Yarn carriers:            FFL base 3,4,5,6,8                               FFR:
-------------
3 - 1st colour

4 - 2nd colour

5 - 3rd colour

6 - 4st colour

8 - choosing

Stitch cams:
-------------
F1 - schema-z

F2 - beginning line

F4 - 2/l patent

F5 - transition between the patent and pattern

F6 - pattern

Program knit a square of 8 needles s wide, because the modelling platinum

has 8 feet. The location of the trouble determines the malfunctioneng magnet,

belonging to the given numbers platinum foot.

Double stitch - slow function of magnet

Missing stitch - contact trouble

The colour of the square shows the work unit.

In case there is a problem in the paires line, the trouble is when going from

the right to the left, if it is in the unpaired line, the trouble is when

going from the left to the right.

The program tests both the enterior and the posterior needlebed, and after

the patent it begins with the anterior needlebed.